TIA568 Wiring Standards

How to decide which wiring pattern to use:

1. Does the job specification call out a wiring pattern?
2. Does the customer/end user have a preference for T568A or T568B?
3. Have patch panels already been purchased for the job? If so, they will probably be either T568A or T568B. The jacks should be wired to the same pattern as the panels.
4. Are you adding on to an existing wiring plant? If so, your new wiring should match the existing wiring.

If none of the factors above apply, either T568A or T568B may be used. It is important to ensure that the workstation connectors and the patch panels are wired to the same pattern. T568B is commonly used in commercial installations, while T568A is prevalent in residential installations.

Click Here for a Full-Color Acrobat pdf file ( 697k ) - Right click to save it to disk.


For a more complete selection of products (no online ordering available at that site), visit the original Lashen Electronics website located at http://www.lashen.com.

Now In: Test Equipment and ToolsCable & Wire TestingCable and Fault Locators → Tempo 501 Tracker II Cable Locator

Model 501 Tracker II Wire Finder and Valve Locator


Model 501 Tracker II Wire Finder and Valve Locator

Tempo 501 Tracker II Cable Locator

E-mail this product to a friend E-mail this product to a friend


Data Sheet (221 Kb)
Previous  Up  Next" 

Tracker II

Model 501 Tracker II offers professional performance in wire locating. With its inductive signal application, the Tracker II can be used on active or dead systems. Now you can trace the path and determine the depth of wires and metallic pipes without having to deactivate the systems. The high frequency transmitter provides range up to 4000 feet and depth to 7 feet. The transmitter offers three methods of connection: direct, inductive coupler or inductive antenna. The 32 inch light-weight receiver provides both audible and visual indications of signal strength for accurate identification. Transmitter output and receiver sensitivity are both fully adjustable for maximum accuracy. The Model 501 Tracker II includes: transmitter assembly, receiver assembly, inductive coupler (clamp), inductive antenna (built-in), two 8 foot test leads with heavy duty alligator clops and a durable polyethylene case.

Technical Specifications

Power requirements: Transmitter - eight "AA" batteries
Receiver - one 9V battery
Battery Life: Transmitter 30 hours
Receiver 10 hours nominal.
Transmitter Frequency: 447.5KHz
Transmitter Power: 40Vp-p (140mW) maximum
Voltage Protection: 240VAC, 500DC
Construction: Transmitter/Receiver - powder coated aluminum
Case - vacuum formed polyethylene
Dimensions: Transmitter - 4.25 x 3 x 3.25"
Case - 33.5 x 8.25 x 3.75"
Weight: 6.7 pounds (complete kit)

Price: $762.40 


Quantity:  
Related Products

HS-1 Headset for 501 and 521
Tempo HS-1 Headset for 501 and 521
     

BES CR1248 Cable Reel Holder
BES CR1248 Cable Reel Holder
BES CR966 Mini Cable Reel Holder
BES CR966 Mini Cable Reel Holder
Tempo PT-T01 Cable Splicer's Knife
Tempo PT-T01 Cable Splicer's Knife
Tempo BLL-200 Buried Line Locator
Tempo BLL-200 Buried Line Locator




HS-1 Headset for 501 and 521
Tempo HS-1 Headset for 501 and 521
     



Product Rating: (0.00)   # of Ratings: 0   (Only registered customers can rate)

There are no comments for this product.