TIA568 Wiring Standards

How to decide which wiring pattern to use:

1. Does the job specification call out a wiring pattern?
2. Does the customer/end user have a preference for T568A or T568B?
3. Have patch panels already been purchased for the job? If so, they will probably be either T568A or T568B. The jacks should be wired to the same pattern as the panels.
4. Are you adding on to an existing wiring plant? If so, your new wiring should match the existing wiring.

If none of the factors above apply, either T568A or T568B may be used. It is important to ensure that the workstation connectors and the patch panels are wired to the same pattern. T568B is commonly used in commercial installations, while T568A is prevalent in residential installations.

Click Here for a Full-Color Acrobat pdf file ( 697k ) - Right click to save it to disk.


For a more complete selection of products (no online ordering available at that site), visit the original Lashen Electronics website located at http://www.lashen.com.

Now In: Test Equipment and ToolsSpecialty TestersFiber Optic Instruments → Tempo 560XL Fiber Optic Power Meter

Fiber Optic Visual Fault Finder


Fiber Optic Visual Fault Finder

Tempo 560XL Fiber Optic Power Meter

E-mail this product to a friend E-mail this product to a friend


Previous  Up  Next" 

XL fiberTOOLS Series

Professional Fiber Optic Instruments

Fiber Optic Power Meter

Measure Insertion Loss and Optical Power

Do not confuse the small size of the 560XL with its ability to provide powerful results. The optical power meter is the perfect tool for installation and testing of fiber optic cabling. The 560XL can be used to measure optical power or used in conjunction with a LED or Laser source to perform insertion loss testing on multimode and singlemode fiber optic cabling.

The 560XL measures optical power at 850nm, 1300nm, 1310nm and 1550nm. It can store reference levels for faster, more efficient testing. The 560XL uses Snap On Connector interface (SOC) to connect FC, SC and ST connectors.

Features

  • Easy to use - three buttons control all functions
  • Loss measurements in (dB) power measurements in (dBm)
  • 0.01dB measurement resolution
  • Multi-wavelength storage - stores and recalls reference power levels for faster, more efficient measurements
  • Snap on connector interface adapts to FC, SC and ST connectors
  • Long battery life - approx. 100 hours continuous operation
  • User selectable auto shut-off
  • Rugged and splash-proof
  • Economically priced
Optical
Calibration Wavelengths 850nm, 1300nm, 1310nm and 1550nm
Power Range -3 dBm to -60 dBm
Accuracy ± 0.25dB
Linearity
+3dBm to -3dBm ±0.5dB
-3dBm to -50dBm ±0.05dB
-50dBm to -60dBm ±0.5dB
Resolution 0.01dB
Power Requirements Two AA size 1.5V batteries (approx. 100 hours continuous operation)
Connector interface FC, SC or ST
Environmental
Operating temperature -15° C to +55° C
Storage temperature -35° C to +70° C
Humidity 0 to 95% non-condensing
Dimensions 7.2 x 14.2 x 3.5 cm (2.8 x 5.6 x 1.4 in.)
Weight 241g (8.5 oz.)
CE EN61010; EN50081-1: 1992; EN55011, Group 1, Class A
EN50082-1: 1992 IEC 801-2, -3, -4

Price: $530.69 


Quantity:  

Channel Vision IR-1200 Simple IR Hub, Connect 1 IR-receiver to 1 IR-emitter, Power Supply included
Channel Vision IR-1200 Simple IR Hub, Connect 1 IR-receiver to 1 IR-emitter, Power Supply included
Leviton HXC7S-1TW Seven-Scene ON, Last Scene OFF, Last Scene DIM/BRIGHT Scene Controller
Leviton HXC7S-1TW Seven-Scene ON, Last Scene OFF, Last Scene DIM/BRIGHT Scene Controller
Channel Vision IR-3002 Dual IR Mini Flashers With Common LED and Feedback IR
Channel Vision IR-3002 Dual IR Mini Flashers With Common LED and Feedback IR
Leviton HXC4A-1TW Three-Address ON/OFF, Group DIM/BRIGHT, All ON/OFF Controller
Leviton HXC4A-1TW Three-Address ON/OFF, Group DIM/BRIGHT, All ON/OFF Controller






Product Rating: (0.00)   # of Ratings: 0   (Only registered customers can rate)

There are no comments for this product.