Search:  

TIA568 Wiring Standards

How to decide which wiring pattern to use:

1. Does the job specification call out a wiring pattern?
2. Does the customer/end user have a preference for T568A or T568B?
3. Have patch panels already been purchased for the job? If so, they will probably be either T568A or T568B. The jacks should be wired to the same pattern as the panels.
4. Are you adding on to an existing wiring plant? If so, your new wiring should match the existing wiring.

If none of the factors above apply, either T568A or T568B may be used. It is important to ensure that the workstation connectors and the patch panels are wired to the same pattern. T568B is commonly used in commercial installations, while T568A is prevalent in residential installations.

Click Here for a Full-Color Acrobat pdf file ( 697k ) - Right click to save it to disk.


For a more complete selection of products (no online ordering available at that site), visit the original Lashen Electronics website located at http://www.lashen.com.
Email Address

Model 1671A Triple-Output 30VDC, 5A Digital Display Power Supply


Show Picture 1Show Picture 2Show Picture 3

Model 1671A Triple-Output 30VDC, 5A Digital Display Power Supply

B&K Model 1671A Triple-Output 30VDC, 5A Digital Display Power Supply

Model 1671A Manual

  • One variable 0 to 30 VDC, 0 to 5 A variable section
  • One 12 VDC fixed section
  • One 5 VDC fixed section
  • Ideal for general electronic servicing, school electronics labs, and powering up hobbyist's projects
Specifications: Model 1671A
Output Voltage: Main Output 0 to 30 VDC
Fixed 12VDC (+- 5%)
Fixed 5 VDC (+-5%)
Output Current: Main Output 0 to 5 A
Fixed 0-500 mA continuous
Fixed 0-500 mA continuous
Constant Voltage Operation
Voltage Regulation
Line (120 VAC +- 10%): <= 0.05% + 10 mV Main
<= 1% (A&B)
Load: (0 to rated load) <= 0.05% + 10 mV
<= 1% (A&B)
Recovery Time: 100us
Ripple & Noise: <= 1mVrms
Temperature Coefficient: <= 300 ppm 0C
Constant Current Operation
Adjustable Current Range: 5% to 100% (Main)
Current Regulation
Line (120 VAC +- 10%): <= 0.4% + 10mA
Load: <= 0.4% + 10mA
Current Ripple: <= 10 mA rms
Metering
Display: 2 digital LCD
Voltmeter Range: 0 to 12 VDC
Voltmeter Accuracy: +- (0.5% reading + 1 digit)
Ammeter Range: 0 - 5 A
Ammeter Accuracy: +- (0.5% reading + 1 digit)
Overload Protection: Current limiting, Reverse polarity, overvoltage, Short circuit
Power Requirements: 108 - 132 VAC, 60 Hz
Power Consumption: 350W
Operating Temperature: 320 to 1040F (00 to 400C). <=75% R. H.
Storage Temperature: 50 to 1580F (-150 to +700C). <=85% R. H.
Dimensions (HxWxD): 4.9" x 8.5" x 11.5" (124mm x 216mm x 292mm)
Weight: 14.3 lbs. (6.5 kg)
Accessories
SUPPLIED: Instruction Manual
OPTIONAL (for all models): TL-SA Hook up cables.

Price: $199.26 


Quantity:  

B&K Model 1652 Triple Output Digital Display DC Power Supply
B&K Model 1652 Triple Output Digital Display DC Power Supply
B&K Model 1651A Triple Output DC Power Supply
B&K Model 1651A Triple Output DC Power Supply
B&K Model 1253 Handheld HDTV Pattern Generator
B&K Model 1253 Handheld HDTV Pattern Generator
BES FIB230 The Fiberfish II
BES FIB230 The Fiberfish II "Four Pack"






Product Rating: (0.00)   # of Ratings: 0   (Only registered customers can rate)

There are no comments for this product.

Powered by AspDotNetStorefront